DMASEL=SOFT, DATAFILTER=DISABLED, RATESELMODE=NOCHANGE, TXPINMODE=OFF, RXPINMODE=SYNCHRONOUS
No Description
SQITHRESH | Signal Quality Indicator threshold |
RXFRCDIS | Receive FRC disable |
RXPINMODE | Receive pin mode 0 (SYNCHRONOUS): Detected payload bits are clocked out on DOUT. Only setups with 1 bit per symbol are supported. 1 (ASYNCHRONOUS): DOUT is continuously providing the sign of the detected frequency deviation before offset compensation. Only 2/4-FSK is supported. |
TXPINMODE | Transmit pin mode 0 (OFF): Pinmode is turned off. Data is gathered from FRC. DOUT/DCLK clocks out transmitted data. 1 (UNUSED): Unused mode 2 (ASYNCHRONOUS): DIN/PRS controls transmitted baud directly. DCLK is set to 0. No support for frame handling nor coding. Only 2-FSK and OOK/ASK can be used. 3 (SYNCHRONOUS): DIN/PRS is sampled on the rising edge of DCLK and used as payload. Frame handling and coding is supported. Only setups with 1 bit per symbol is supported. |
DATAFILTER | Datafilter 0 (DISABLED): Datafilter disabled 1 (SHORT): Short datafilter enabled. 2*RXBRFRAC should be more than 3. 2 (MEDIUM): Medium datafilter enabled. 2*RXBRFRAC should be more than 4. 3 (LONG): Long datafilter enabled. 2*RXBRFRAC should be more than 5. 4 (LEN6): Datafilter with length 6 enabled. 2*RXBRFRAC should be more than 6. 5 (LEN7): Datafilter with length 7 enabled. 2*RXBRFRAC should be more than 7. 6 (LEN8): Datafilter with length 8 enabled. 2*RXBRFRAC should be more than 8. 7 (LEN9): Datafilter with length 9 enabled. 2*RXBRFRAC should be more than 9. |
BRDIVA | Baudrate division factor A |
BRDIVB | Baudrate division factor B |
DEVMULA | Deviation multiplication factor A |
DEVMULB | Deviation multiplication factor B |
RATESELMODE | Rate select mode 0 (NOCHANGE): No rate change. BRDIVA/DEVMULA is used for entire frame. 1 (PAYLOAD): Change rate for payload. BRDIVA/DEVMULA is used for header and BRDIVB/DEVMULB is used for payload. 2 (FRC): FRC selects between BRDIVA/DEVMULA and BRDIVB/DEVMULB for each symbol in the payload. Header uses BRDIVA/DEVMULA. 3 (SYNC): The configured/detected syncword decides the settings used for the payload. SYNC0 uses BRDIVA/DEVMULA and SYNC1 uses BRDIVB/DEVMULB. Header uses BRDIVA/DEVMULA. |
DEVWEIGHTDIS | Deviation weighting disable. |
DMASEL | DMA select. 0 (SOFT): SOFTVAL field 1 (CORR): CORRVAL field 2 (FREQOFFEST): FREQOFFEST field 3 (POE): POE field |